HEIGHT PRESETTER WP ( Necessities of machining )
Reference point of work piece can be measured very quickly and accurately without damage of tool teeth. High Precision Measurement Easy to measure tooling off-set values on the machine accurately. Hard wearing powerful magnetic Base. Powerful magnetic base (700N) makes it suitable for use on manual machine as well as Vertical/Horizontal Machining Centres and NC Lathes. Swarf Removal The Magnetic Base can be switched on and off allowing the reference face to keep clean. Plunger Head is given a Anti-Rust Rubber Seal. Proximity Lamp The red lamp is activated when the plunger comes within the measuring range of the reference height. IP43 International protect Protect the precision equipment from dust and water spray. * It does not protect internal equipment from coolant injection or submersion in water.
IP43 International Protection
HP- 100WP
φ 30
φ 55
Sticking Face
62
19
90
Sticking Face
81
Red Lamp
★ 2 of Batteries LR44(HC) are supplied as standard with both of HP-100 and HP-150 .
HP- 150WP
φ 30
φ 55
Sticking Face
62
19
90
Sticking Face
81
Red Lamp
Adjustment of Reference Point No setting gauge plate is required to adjust Zero Point. Push Plunger down by hand, and adjust the large hand to the Zero Scale of DialGauge. The small hand indicates “-3” at this time.)
< Tool Length Compensation > Machine zero Point of Z Axis
Example of usage at Vertical Machining Centre.
Example of Program G92 Z100 G43 Z0 H01
Compensation Value=H01
Also suitable for use of Micron Adjustment of Boring Arbor.
G92Z100
HP-100WP
Z=0
Work piece
Example of usage at NC Lathe.
145
Powered by FlippingBook